- Constructed of quality, heavy duty materials for long life
- Outside machine height is 12.5′, width 8′, length of oven is 25′ (if the oven extension is purchased, it is 25′ in length). Infeed deck is 10′, and outfeed deck is 10′; inside dimension of oven is 5.5’ W x 9’ H
- Approximate weight is 20,000 lbs for the oven and 10,000 lbs for the oven extension
- Machine requires 480 volt, 3 phase, 300 amp electrical service
- Powered with efficient 3-phase frequency drive motor
- The oven’s main insulator is used in applications up to 1,900°F; it keeps the heat in while the outside of the oven remains cool to the touch
- A large blower fan installed on top of the oven draws air from inside the oven and blows the air back down across the many heating elements in the pressurized air boxes located each side of the oven; then the hot air is blown through the many holes in the pressurized air box into the product as it moves through the oven
- The machine has zero puddling inside the oven
- Air curtains above oven entrance and exit doors minimize loss of heat for incoming and exiting products saving time and money
- 2 – 81X kiln chains are placed 36” on center to accommodate product and weather high heat
- Simple user interface and display control panel is easy to operate power, machine heat, conveyor, blower fan and air curtains
- Can run machine in batch mode or in continuous flow thru mode (product on conveyor always in motion at a speed predetermined for treatment cycle time)
- Product is placed on infeed deck and travels through entrance doors and exits on the outfeed deck
- The machine can be configured to “flip flop” infeed and outfeed decks based on placement inside your building
- The HT Sanitizer Continuous Heat Treat System can be moved in the future as your business and operations footprint changes
- The machine is designed for indoor use resulting in more consistent performance since it is out of the weather elements, especially in winter climates
- Our company has low cost options to protect machine if current floor space is at a minimum
- Minimal maintenance of machine